Saturday, March 29, 2008

Minimum Trap/Waste Outlet Sizes for Plumbing Fixtures

Q: What are the Minimum Trap/Waste Outlet Sizes for Plumbing Fixtures, the the NYC Building Code?

A: Refer to Table 16-6 for the Minimum Trap Sizes, as restated below:

Fixtures & Trap Sizes:
Bathtub (with or without overhead Shower 1 1/2"
Bidets 1 1/2"
Combination Sink and Wash (Laundry Tray) 2"
Dental Unit or Cuspidor 1 1/2"
Drinking Fountain 1 1/2"
Dishwasher, Commercial 2"
Dishwasher, Domestic 1 1/2"
Floor Drain 3"
Funnel Drain 1 1/2"
Kitchen Sink, Domestic 2"
Laboratory Cup Sink 1 1/2"
Laboratory Sink 2"
Lavatory, Common 1 1/2"
Lavatory, Barber, Beauty Parlor, or Surgeon's 1 1/2"
Lavatory, multiple type (was fountain or sink) 1 1/2"
Laundry Tray (1 or 2 compartments) 1 1/2"
Laundry Standpipe 2"
Shower, Stall 2"
Shower, Gang 3"
Sink (Surgeon's) 1 1/2"
Sink (flushing rim type, flush valve supplies) 3"
Sink (service type with Trap Standard) 3"
Sink, Commercial (Pot, Scullery or sim) 2"
Sterilizers 3"
Urinal (Pedestal) 3"
Urinal (Stall Type) 2"
Urinal (Wall Lip Type) 2"
Urinal (Women's) 3"
Water Closet (Waste Outlet) 3"